The built-in Verba monitoring solution supports SNMP v2 and v3 traps, using a Verba specific set of SNMP Trap OIDs. Please refer to the following article: Alerts
In order for it to work, you need to configure it on all servers and desktop components installed in your Verba system, such as:
Verba System Monitor Service is activated by default on all Verba systems and is configured for email sending. However it still worth checking that the service is not disabled and is actually running. |
The SNMP traps are sent by the Verba System Monitor Service. In order to configure and use it, the service should be activated and started.
In the panel on the right, configure the parameters required for the SNMP version selected:
Parameter | Description | Required | Default value | Used for SNMP version |
---|---|---|---|---|
Target Hostname or Ip Address | The host name or IP address to which the SNMP alert is sent. | All | ||
Trap Community | The community to which the SNMP alert is sent. | SNMP version 2 | ||
Trap Port | The port number of the SNMP target. | 162 | All | |
User name | The user name used to connect to the SNMP target. | Yes | SNMP version 3 | |
Authentication type | The authentication method used to connect to the SNMP target. Possible values:
| MD5 | SNMP version 3 | |
Password | The password used to connect to the SNMP target. | Yes | SNMP version 3 | |
Privacy type | The encryption method used to secure the connection to the SNMP target. Possible values:
| DES | SNMP version 3 | |
Privacy key | The encryption key used to secure the connection to the SNMP target. | SNMP version 3 | ||
Engine ID | Unique identifier for the VFC server on which the trap is configured. Setting a value is optional, because the system generates the value automatically if the field is left empty. | SNMP version 3 |